Conversion from Gallons per hour to Cubic feet per minute

=

Invert

Formula to convert Gallons per hour (gal/h) to Cubic feet per minute (ft³/min)

More information

Gallons per hour to Cubic feet per minute conversion table

Gallons per hour (gal/h)Cubic feet per minute (ft³/min)
1 Gallon per hour0.00267572755412 ft³/min
2 Gallons per hour0.00535145510824 ft³/min
3 Gallons per hour0.00802718266236 ft³/min
4 Gallons per hour0.0107029102165 ft³/min
5 Gallons per hour0.0133786377706 ft³/min
10 Gallons per hour0.0267572755412 ft³/min
20 Gallons per hour0.0535145510824 ft³/min
25 Gallons per hour0.066893188853 ft³/min
50 Gallons per hour0.133786377706 ft³/min
100 Gallons per hour0.267572755412 ft³/min

Volumetric flow rate reference points

ReferenceGallons per hour (gal/h)Cubic feet per minute (ft³/min)
A domestic shower118.783 gal/h0.317832 ft³/min
A kitchen tap131.982 gal/h0.353147 ft³/min
A garden hose197.972 gal/h0.52972 ft³/min
The Amazon river1.65505 × 1011 gal/h442845921 ft³/min

Try our other unit converters

LengthMassTemperatureEnergyVolumeSpeedTimeDataPressureFrequencyData-transfer rateVolumetric flow rateAngleArea

Information about the Gallon per hour (gal/h)

The gallon per hour is a unit of volumetric flow rate equal to one imperial gallon passing a point every hour. Its symbol is gal/h, often abbreviated GPH. One imperial gallon is 4.54609 litres, so this unit describes the slow, sustained flows that matter over the length of a working day rather than a minute.

Fuel consumption is its most durable use. A boat's diesel engine burns 1 to 5 gallons per hour at cruising speed, a generator 0.5 to 2, and an agricultural tractor 2 to 4. Because such engines run at steady load for hours, the hourly figure multiplied by the hours of running gives the fuel bill directly, which is why boat and plant operators still think in these terms.

Oil-fired heating uses the unit for burner nozzles. A domestic oil boiler is fitted with a nozzle rated in gallons per hour — 0.5, 0.65 or 0.85 for a house — and that rating, multiplied by the calorific value of the oil, gives the heat output. Changing the nozzle changes the output, so the nozzle size on the burner label is effectively the rating of the appliance.

Water treatment and dosing are described the same way. A softener's regeneration flow, a chlorinator's feed rate and a chemical dosing pump on a cooling system are all set in gallons per hour, chosen so that the treated water leaves the plant with the concentration the process requires over a whole shift.

Older domestic water fittings carried the unit too. A header tank's fill rate, a cistern's refill and a slow-running standpipe were measured in gallons per hour in British practice, and the same figure told a householder how long a tank would take to recover after a bath had emptied it.

For scale, one gallon per hour is about 4.5 litres per hour, and 220 gallons per hour is about a cubic metre per hour. A rate of one gallon per hour would fill a domestic bath in about eighty hours, which is a fair reminder that this unit measures processes, not deliveries.

One gallon per hour equals about 4.546 litres per hour, about 0.004546 cubic metres per hour, or about 1.201 US gallons per hour.


Information about the Cubic foot per minute (ft³/min)

The cubic foot per minute is a unit of volumetric flow rate equal to one cubic foot passing a point every minute. Its symbol is ft³/min, universally abbreviated CFM. It is the working unit of air movement in the English-speaking world: fans, compressors, extractors and air conditioners are all sold by it.

Ventilation is specified in it throughout North America. An extractor fan over a domestic cooker is rated at 200 to 400 CFM, a bathroom fan at 50 to 110, a large commercial rooftop unit at several thousand, and a whole-house fan at 3,000 or more. Building codes give minimum rates per person or per square foot of floor, and the designer multiplies to reach the fan size.

Compressed air uses it with a qualifier that matters. A compressor is rated in standard cubic feet per minute, referred to a fixed temperature, pressure and humidity, because a cubic foot of air at 100 pounds per square inch contains far more air than one at atmospheric pressure. A tool that consumes 5 SCFM will starve on a compressor rated 5 CFM of displacement, since displacement and delivery are not the same number.

Dust extraction in woodworking is a familiar case. A table saw needs about 350 CFM at the port to capture chips, a planer 400 to 800, and a shop with several machines running needs the sum plus an allowance for duct losses. Since a blast gate closes off unused branches, the same collector can serve the whole shop one machine at a time.

Engine and vehicle work uses it too. A carburettor is rated in CFM, an engine's airflow at peak power is quoted in CFM, and a radiator fan moves 1,500 to 3,000. The rating is what determines whether the airflow matches the engine's demand at the speed it is designed to work hardest.

The conversions are worth learning: 1 CFM is about 0.4719 litres per second, about 1.699 cubic metres per hour, and 2,119 CFM is one cubic metre per second. European and American catalogues describe the same equipment in these different units, and the numbers only match once one of them is converted.

One cubic foot per minute equals about 0.4719 litres per second, about 1.699 cubic metres per hour, or about 7.481 US gallons per minute.