Conversion from 5 Gallons per second to Cubic millimeters per second

=

Invert

Formula to convert Gallons per second (gal/s) to Cubic millimeters per second (mm³/s)

More information

Gallons per second to Cubic millimeters per second conversion table

Gallons per second (gal/s)Cubic millimeters per second (mm³/s)
1 Gallon per second4546090 mm³/s
2 Gallons per second9092180 mm³/s
3 Gallons per second13638270 mm³/s
4 Gallons per second18184360 mm³/s
5 Gallons per second22730450 mm³/s
10 Gallons per second45460900 mm³/s
20 Gallons per second90921800 mm³/s
25 Gallons per second113652250 mm³/s
50 Gallons per second227304500 mm³/s
100 Gallons per second454609000 mm³/s

Volumetric flow rate reference points

ReferenceGallons per second (gal/s)Cubic millimeters per second (mm³/s)
A domestic shower0.0329954 gal/s150000 mm³/s
A kitchen tap0.0366615 gal/s166667 mm³/s
A garden hose0.0549923 gal/s250000 mm³/s
The Amazon river45973573 gal/s2.09 × 1014 mm³/s

Try our other unit converters

LengthMassTemperatureEnergyVolumeSpeedTimeDataPressureFrequencyData-transfer rateVolumetric flow rateAngleArea

Information about the Gallon per second (gal/s)

The gallon per second is a unit of volumetric flow rate equal to one imperial gallon passing a point every second. Its symbol is gal/s. The imperial gallon is 4.54609 litres, defined in 1824 as the volume of ten pounds of water at a stated temperature, so one gallon per second moves about four and a half litres — and, conveniently, about ten pounds — every second.

Firefighting is the discipline that works at this scale. A hose reel delivers a fraction of a gallon per second, a standard hose line 1 to 2, and a major pumping appliance 10 or more. British fire service practice quoted pump capacities in gallons per minute for most of the twentieth century, and the per-second figure is what a hydraulic calculation of pressure loss in the hose actually uses.

Large pumps and water mains reach it easily. A borehole pump on a farm might deliver half a gallon per second, a district water main several tens, and a river intake for a power station hundreds. Since the gallon of water weighs ten pounds, a flow in gallons per second converts to a mass flow in stones per second by dividing by 1.4, an arithmetic that older British engineering handbooks used freely.

Flood and drainage engineering in Britain used the unit until metrication. Culvert capacities, pumping station ratings and land drainage schemes were designed in gallons per second or per minute, and much of the surviving infrastructure still carries plates giving its capacity in those terms, which anyone assessing an old asset must convert with care.

The imperial gallon must be distinguished from the American one, which is 3.78541 litres — about twenty per cent smaller. A pump rated 10 gallons per second delivers 45.5 litres per second in Britain and 37.9 in the United States, a difference far too large to ignore in any calculation of capacity or of cost.

For scale, one gallon per second fills a domestic bath in about twenty-five seconds, and 0.22 gallons per second is one litre per second. A flow of ten gallons per second is a small stream, running at about 45 litres per second.

One gallon per second equals about 4.546 litres per second, about 0.004546 cubic metres per second, or about 1.201 US gallons per second.


Information about the Cubic millimeter per second (mm³/s)

The cubic millimetre per second is a unit of volumetric flow rate equal to one cubic millimetre passing a point every second. Its symbol is mm³/s. A cubic millimetre is the volume of a grain of coarse salt, so this unit describes flows small enough that a full second delivers something barely visible.

Additive manufacturing made it a working number. A fused-filament printer's extruder is limited by how fast it can melt plastic, and that limit is expressed as a volumetric rate: a standard hot end manages 8 to 12 cubic millimetres per second, a high-flow one 25 to 40. Slicing software converts it into a print speed by dividing by the cross-section of the extruded line, which is why the same printer runs faster with a thin layer than a thick one.

Inkjet printing works at a far smaller scale still. A single droplet is a few picolitres, and a print head firing thousands of droplets per second from hundreds of nozzles adds up to only a few cubic millimetres per second in total. The unit is convenient here because it sits between the droplet and the ink cartridge without needing scientific notation.

Machining uses it for the material-removal rate of fine work. Wire electrical-discharge machining removes 20 to 100 cubic millimetres per minute, which is under two per second, and micro-milling with a tool a fraction of a millimetre across is slower again. Since removal rate governs both time and tool wear, it is the number a process engineer optimises.

Medical and laboratory devices are specified here when the volumes are tiny. Microfluidic chips, capillary electrophoresis and some infusion applications move flows of this order, and a cubic millimetre per second is exactly one microlitre per second, which is why the same rate appears under two names in different catalogues.

The unit's relation to the litre is worth holding: a million cubic millimetres make a litre, so a thousand cubic millimetres per second is one litre per second. A flow of ten cubic millimetres per second, typical of a 3D printer, would take about twenty-eight hours to fill a one-litre bottle.

One cubic millimetre per second equals 0.001 millilitres per second, 0.06 millilitres per minute, or one microlitre per second.